FUNCTION
Select vertical expaned character mode
CODE
<ESC> “h” “1” or <ESC> “h” <1>
(1B)
H (68)H (31)H or (1B)H (68)H (01)H
OUTLINE
Prints characters two times the normal vertical size after the
code is received.
However, the bit image mode <ESC> “K” and <ESC> “L”
are excluded.
NOTE
(1) When combined with the <SO> code, this code enables
printing of the characters in two times the normal vertical
and horizontal size.
(2) This code is not combined with the inverted print mode
<SI> code.
(3) For the 6 × 12 dots IBM block graphic (the characters
code table (B0)
H-(DF)H and (F4)H-(F5)H of IBM charac-
ter set #1 and #2) of the font construction, vertical
enlargement is not available.
(4) The relationship of the vertically enlarged character and
the normal character is matched at the lower level.
(5) Feed the paper a minimum of one line before printing
with this code.
FUNCTION
Cancel vertical expanded character mode
CODE
<ESC> “h” “0” or <ESC> “h” <0>
(1B)
H (68)H (30)H or (1B)H (68)H (00)H
OUTLINE
Cancels vertical expanded character mode